LINE FREQUENCY

  • 60mA Spring Balance Mobile

    60mA Spring Balance Mobile

    View Description
    Model 60S
    Radiography Rating 15-60mA stations 35KVP to 100 KVP in 15 Step of 5 KVP each
    Output 5 KW
    Rectification Full wave Rectified
    Timer Electronic Solid State in 24 Steps 0.06 to 10 sec.
    Digital Display Digital Display of mAs. KV & mA
    X – Ray Tube BEL DSA-3/Imported
    Power Supply 1 Phase / 3 Phase 230V AC / 440 V 50 Hz
    Line Regulation 10% 0.6 max
    Protection Electronic over-load Protection
    Tube Stands Spring Counter Balanced Mobile Can easily transported in elevators/lift because of low height.
    Mobility High Mobility
  • 60mA Static

    60mA Static

    View Description
    Model 60S
    Radiography Rating 15-60mA stations 35KVP to 100 KVP in 15 Step of 5 KVP each
    Output 5 KW
    Rectification Full wave Rectified
    Timer Electronic Solid State in 24 Steps 0.06 to 10 sec.
    Digital Display Digital Display of mAs. KV & mA
    X – Ray Tube BEL DSA-3/Imported
    Power Supply 1 Phase / 3 Phase 230V AC / 440 V 50 Hz
    Line Regulation 10% 0.6 max
    Protection Electronic over-load Protection
    Compatible Tube Stands Floor to ceiling
    Floor to ceiling with fluoroscopy
    Floor to Ceiling with SFD
    Compatible tables Monocon, Multicon, Motocon, Flocon
  • 100mA Counter balance Mobile

    100mA Counter balance Mobile

    View Description
    Model 100S
    Radiography Rating 30-10m A stations 35 KVP to 100 KVP in 15 Stem of 5 KVP each
    Output 8KW
    Rectification Full Wave rectified
    Timer Electronic Solid State in 24 Steps 0.06 to 10 sec.
    Digital Display Digital Display of MaS. KV & mA
    X – Ray Tube BEL DSA – 3/Imported
    Power Supply 230 Voltage AC, 15 Amps.
    Requirement 50Hz, Single Phase
    Line Regulation 10% 0.4 max
    Protection Electronic Over-load Protection
    Tube Stands Counter Balanced Mobile Can easily transported in elevators/lift because of low height.
    Mobility High Mobility
  • 100mA Spring balance Mobile

    100mA Spring
    balance Mobile

    View Description
    Model 100S
    Radiography Rating 30-10mA stations 35 KVP to 100 KVP in 15 Stem of 5 KVP each
    Output 8KW
    Rectification Full Wave rectified
    Timer Electronic Solid State in 24 Steps 0.06 to 10 sec.
    Digital Display Digital Display of MaS. KV & mA
    X – Ray Tube BEL DSA – 3/Imported
    Power Supply 230 Voltage AC, 15 Amps.
    Requirement 50Hz, Single Phase
    Line Regulation 10% 0.4 max
    Protection Electronic Over-load Protection
    Tube Stands Spring Counter Balanced Mobile Can easily transported in elevators/lift because of low height.
    Mobility High Mobility
  • 100mA Static

    100mA Static with
    horizontal Bucky table

    View Description
    Model 100S
    Radiography Rating 30-10mA stations 35 KVP to 100 KVP in 15 Stem of 5 KVP each
    Output 8KW
    Rectification Full Wave rectified
    Timer Electronic Solid State in 24 Steps 0.06 to 10 sec.
    Digital Display Digital Display of MaS. KV & mA
    X – Ray Tube BEL DSA – 3/Imported
    Power Supply 230 Voltage AC, 15 Amps.
    Requirement 50Hz, Single Phase
    Line Regulation 10% 0.4 max
    Protection Electronic Over-load Protection
    Tube Stands Floor to ceiling Floor to ceiling with fluoroscopy Floor to Ceiling with SFD
    Mobility High Mobility
  • 100mA Static with multi position table

    300mA Static with multi position table

    View Description
    Model 300mA
    Radiography Rating 45-125 KVP(In step of 1 KVP each)
    Output 30 KW
    Rectification Full wave Rectified
    Timer Electronic Solid State in 24 Steps 0.02 to 5 sec.
    Digital Display Digital Display of mAs. KV & mA
    Technical Selection 50mA,100mA,200mA and 300mA
    Power Supply 1 Phase / 3 Phase 230V AC / 440 V 50 Hz
    Line Regulation 10% 0.6 max
    Protection Electronic over-load Protection
    Tube head with Collimator BEL/Imported Rotating Anode, Dual focus 20/40 KW X-ray tube unit
    Compatible Tube Stands Floor to ceiling
    Floor to ceiling with fluoroscopy
    Floor to Ceiling with SFD
    Compatible tables Monocon, Multicon, Motocon, Flocon
  • 300mA and 500mA

    500mA with motorized Table

    View Description
    Model 500mA
    Radiography Rating 45-125 KVP(In step of 1 KVP each)
    Output 40 KW
    Rectification Full wave Rectified
    Timer Electronic Solid State in 24 Steps 0.01 to 5 sec.
    Digital Display Digital Display of mAs. KV & mA
    Technical Selection 50mA,100mA,200mA, 300mA and 500mA
    Power Supply 1 Phase / 3 Phase 230V AC / 440 V 50 Hz
    Line Regulation 10% 0.6 max
    Protection Electronic over-load Protection
    Tube head with Collimator BEL/Imported Rotating Anode, Dual focus 20/40 KW X-ray tube unit
    Compatible Tube Stands Floor to ceiling
    Floor to ceiling with fluoroscopy
    Floor to Ceiling with SFD
    Compatible tables Monocon, Multicon, Motocon, Flocon
  • C Arm (IMAGER 2000S)

    C Arm (IMAGER 2000S)

    View Description
    IMAGER 2000S
    Type of Generator Full Wave Rectifier (2 Pulse)
    Tube type Double Focus Stationary Anode
    X – Ray Tube Fluoro : 0.6mm x 0.6mm
    Radio : 1.5mmx1.2mm
    Fluoroscopic KVP 40-110 KVp (Single Step)
    Fluoroscopic mA 0.1-3.0mA (Continuous)
    Fluoroscopic Timer Temperature Controlled
    Radiographic KVp 40-110 KVp (Single Step)
    Radiographic mAs Upto 220 mAs
    Power Requirement 220 V/50 Hz 2.4 Kw
    Type of Image 6” or 9” Image
    Intensifier Intensifier with housing and microprocessor controlled power supply
    CCD Camera High Poer Optics with ½” BW CCD Camera with high resolution output.
    TV Monitors 15”/17” high resolution monitors mounted on mobile trolley
  • C Arm (IMAGER 2000HFS)

    C Arm (IMAGER 2000HFS)

    View Description
    IMAGER 2000HFS
    Type of Generator High Frequency
    Tube type Double Focus Stationary Anode
    X – Ray Tube Fluoro : 0.6mm x 0.6mm
    Radio : 1.5mmx1.5mm
    Fluoroscopic KVP 40-110 KVp (Single Step)
    Fluoroscopic mA 0.1-3.0mA (Continuous)
    Fluoroscopic Timer Temperature Controlled
    Radiographic KVp 40-110 KVp (Single Step)
    Radiographic mAs Upto 220 mAs
    Power Requirement 220 V/50 Hz 3.5 Kw
    Type of Image 6” or 9” Image
    Intensifier Intensifier with housing and microprocessor controlled power supply
    CCD Camera High Poer Optics with ½” BW CCD Camera with high resolution output.
    TV Monitors 15”/17” high resolution monitors mounted on mobile trolley
  • C Arm (IMAGER 2000HFR)

    C Arm (IMAGER 2000HFR)

    View Description
    IMAGER 2000HFR
    Type of Generator High Frequency
    Tube type Double Focus Stationary Anode
    X – Ray Tube Fluoro : 0.3mm x 0.3mm
    Radio : 0.6mmx0.6mm
    Fluoroscopic KVP 40-110 KVp (Single Step)
    Fluoroscopic mA 0.1-3.0mA (Continuous)
    Fluoroscopic Timer Temperature Controlled
    Radiographic KVp 40-110 KVp (Single Step)
    Radiographic mAs Upto 220 mAs
    Power Requirement 220 V/50 Hz 3.5 Kw
    Type of Image 6” or 9” Image
    Intensifier Intensifier with housing and microprocessor controlled power supply
    CCD Camera High Poer Optics with ½” BW CCD Camera with high resolution output.
    TV Monitors 15”/17” high resolution monitors mounted on mobile trolley
  • Portable-30mA

    Portable-30mA

    View Description
    Output 30mA at 52 KV
    20mA at 68 KV
    15mA at 85 KV
    Timer 0.06mA to 6.0
    23 Steps
    Tube 1.5 mm sq. Focal Spot X-Ray tube
    Input 230V, 15 Amps
    L. V. Compensation 210 to 250V
    Beam Limination Cone with Centering Device
    Weight 15 Kgs.
    Dimension (mm) 250x175x250
  • Portable-30mA

    Portable-50mA

    View Description
    Output 50mA at 50 KV
    40mA at 65 KV
    30mA at 85 KV
    Timer 0.06mA to 6.0
    23 Steps
    Tube 1.5 mm sq. Focal Spot X-Ray tube
    Input 230V, 15 Amps
    L. V. Compensation 210 to 250V
    Beam Limination Cone with Centering Device
    Weight 18 Kgs.
    Dimension (mm) 300x200x300